Carbon footprint estimator for AWS instances

Curious about the power consumption and carbon footprint of an EC2 instance? As part of the first Measure challenge, get an estimation below. This initiative is still a work in progress, data is provided as-is for open contribution purposes and without warranty.

Carbon footprint estimator for AWS instances

Let's go

1

Measure​

Define your EC2 workload and get its carbon footprint

2

Reduce​

Use this information to optimize your infrastructure

3

Share

Help us raise awareness around this challenge

Select your workload

Calculator
Hour(s)

Your Estimation

Detailed calculation for:
Scope 2
194.0

Watts
@50% load

x
1.2

PUE
for US East (N. Virginia)

x
415.755

gCO₂eq/kWh
for US East (N. Virginia)

1000
+
Scope 3
33.4

gCO₂eq
for c6g.metal

x
8766 Hour(s)
Just estimated the carbon footprint of my EC2 workload: for 8766 hour(s) of c6g.metal in us-east-1 the result is 1141225.9 gCO₂eq (848441.5 gCO₂eq for running the instance and 292784.4 gCO₂eq for its manufacturing). Give it a try too!

Just estimated the carbon footprint of my EC2 workload: for 8766 hour(s) of c6g.metal in us-east-1 the result is 1141225.9 gCO₂eq (848441.5 gCO₂eq for running the instance and 292784.4 gCO₂eq for its manufacturing). Give it a try too!

Raw data for one hour of computing:
Instance Load Idle 10% 50% 100%
Instance Estimated Power Consumption 73.0
Watts
116.1
Watts
194.0
Watts
259.6
Watts
Carbon Emissions from Running (Scope 2) 36.4
gCO₂eq
57.9
gCO₂eq
96.8
gCO₂eq
129.5
gCO₂eq
Carbon Emissions from Manufacturing (Scope 3) + 33.4
gCO₂eq

This estimator relies on a dataset published under a Creative Commons Attribution 4.0 International License aggregating EC2 specifications, power consumption and manufacturing footprint estimation data for each instance type.

Scroll to Top

Instance Specifications

Release Date: December 2019
Instance vCPU: 64
Total vCPU: 64
Processor: Graviton2
Instance memory: 128GB
Total memory: 128GB
Storage type: EBS
GPU: N/A

Region information

Region slug: us-east-1
Region name: US East (N. Virginia)
Region country: United States
Electricity Carbon Intensity
415.755 gCO₂eq/kWh
Region PUE
1.2

Power Consumption

Estimated power consumed by an instance according to its load level (idle, 10% load, 50% load, 100% load). This number doesn’t include the PUE and only reflects the server consumption.

Scope 2

Carbon emissions related to running the instance, including the datacenter PUE

Scope 3

Carbon emissions related to manufacturing the underlying hardware